{"id":1447591870561,"title":"Stego Setpoint Thermostat | Adjustable | Normally Closed","handle":"block-heater-thermostat","description":"\u003cdiv class=\"model\" style=\"padding: 0px;\"\u003e\n\u003ch1\u003eAdjustable Setpoint Thermostat\u003c\/h1\u003e\n\u003ch2\u003eJust set it and forget it.  Block heaters should not be left on all the time. Set the air temperature to 10 degrees for example, and when it's warm outside, your heater will turn off. \u003c\/h2\u003e\n\u003ch3\u003eHelp prevent your heaters from working overtime and burning out. Adding a air temperature switch like this one will save you time and money.  Prolong the life of your block heater and have it turn off automatically when not needed.  \u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" light model\" style=\"padding: 3px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNormally Closed Adjustable Thermostat (red temperature dial): Thermostat opens on temperature rise. Uses may include regulating heaters or switching signal devices when temperature has fallen below the setpoint value\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"margin-top: 0px;\" width=\"600px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGENERAL SPECIFICATIONS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Difference\u003c\/td\u003e\n\u003ctd\u003e12.6°F ±7°F tolerance (7K ± 4K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Element\u003c\/td\u003e\n\u003ctd\u003eThermostatic bimetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eSnap-action contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e15 A resistive \/ 2A inductive @ 120 VAC;\u003cbr\u003e10 A resistive \/ 2A inductive @ 250 VAC; DC 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Inrush Current\u003c\/td\u003e\n\u003ctd\u003eAC 16 A for 10 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA (all voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal, clamping torque 0.5 Nm max.; \u003cbr\u003esolid wire - 14 AWG max. (2.5 mm2); \u003cbr\u003estranded wire (with wire end ferrule) - 16 AWG (1.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlastic, UL 94V-0, light gray\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eClip for 35 mm DIN rail, EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-49° to 176°F (-45° to 80°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.09 lb (40 g)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA, UL Recognized File No. E164102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","published_at":"2016-11-12T18:08:00-05:00","created_at":"2018-10-30T12:37:48-04:00","vendor":"Aurora Generators","type":"Accessories","tags":["accessory","cold","heater","thermostat","weather"],"price":2400,"price_min":2400,"price_max":2400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12468943290465,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"01140900","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Stego Setpoint Thermostat | Adjustable | Normally Closed","public_title":null,"options":["Default Title"],"price":2400,"weight":454,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1559\/9731\/products\/thermostat_bf0e6ce1-aae7-4a39-96c7-1a381572800a.png?v=1543856982","\/\/cdn.shopify.com\/s\/files\/1\/1559\/9731\/products\/2342345_d573b407-eb69-4520-a7f5-e61fc735388c.png?v=1543856982","\/\/cdn.shopify.com\/s\/files\/1\/1559\/9731\/products\/4634_65ab4394-8e13-4e1b-a912-3808386dc5db.png?v=1543856982"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1559\/9731\/products\/thermostat_bf0e6ce1-aae7-4a39-96c7-1a381572800a.png?v=1543856982","options":["Title"],"content":"\u003cdiv class=\"model\" style=\"padding: 0px;\"\u003e\n\u003ch1\u003eAdjustable Setpoint Thermostat\u003c\/h1\u003e\n\u003ch2\u003eJust set it and forget it.  Block heaters should not be left on all the time. Set the air temperature to 10 degrees for example, and when it's warm outside, your heater will turn off. \u003c\/h2\u003e\n\u003ch3\u003eHelp prevent your heaters from working overtime and burning out. Adding a air temperature switch like this one will save you time and money.  Prolong the life of your block heater and have it turn off automatically when not needed.  \u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\" light model\" style=\"padding: 3px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNormally Closed Adjustable Thermostat (red temperature dial): Thermostat opens on temperature rise. Uses may include regulating heaters or switching signal devices when temperature has fallen below the setpoint value\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"margin-top: 0px;\" width=\"600px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGENERAL SPECIFICATIONS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Difference\u003c\/td\u003e\n\u003ctd\u003e12.6°F ±7°F tolerance (7K ± 4K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Element\u003c\/td\u003e\n\u003ctd\u003eThermostatic bimetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eSnap-action contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e15 A resistive \/ 2A inductive @ 120 VAC;\u003cbr\u003e10 A resistive \/ 2A inductive @ 250 VAC; DC 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Inrush Current\u003c\/td\u003e\n\u003ctd\u003eAC 16 A for 10 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA (all voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal, clamping torque 0.5 Nm max.; \u003cbr\u003esolid wire - 14 AWG max. (2.5 mm2); \u003cbr\u003estranded wire (with wire end ferrule) - 16 AWG (1.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlastic, UL 94V-0, light gray\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eClip for 35 mm DIN rail, EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-49° to 176°F (-45° to 80°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.09 lb (40 g)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA, UL Recognized File No. E164102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e"}

Stego Setpoint Thermostat | Adjustable | Normally Closed

Product Description
$24.00
Maximum quantity available reached.

Adjustable Setpoint Thermostat

Just set it and forget it.  Block heaters should not be left on all the time. Set the air temperature to 10 degrees for example, and when it's warm outside, your heater will turn off. 

Help prevent your heaters from working overtime and burning out. Adding a air temperature switch like this one will save you time and money.  Prolong the life of your block heater and have it turn off automatically when not needed.  

 

Normally Closed Adjustable Thermostat (red temperature dial): Thermostat opens on temperature rise. Uses may include regulating heaters or switching signal devices when temperature has fallen below the setpoint value

 

GENERAL SPECIFICATIONS
Switching Difference 12.6°F ±7°F tolerance (7K ± 4K)
Sensor Element Thermostatic bimetal
Contact Type Snap-action contact
Contact Resistance <10 mΩ
Service Life >100,000 cycles
Max. Switching Capacity 15 A resistive / 2A inductive @ 120 VAC;
10 A resistive / 2A inductive @ 250 VAC; DC 30 W
Max. Inrush Current AC 16 A for 10 sec.
Minimum Load 20 mA (all voltages)
Connection 2-pole terminal, clamping torque 0.5 Nm max.;
solid wire - 14 AWG max. (2.5 mm2);
stranded wire (with wire end ferrule) - 16 AWG (1.5 mm2
Housing Plastic, UL 94V-0, light gray
Mounting Clip for 35 mm DIN rail, EN 60715
Mounting Position Vertical
Operating Storage Temperature -49° to 176°F (-45° to 80°C)
Weight 0.09 lb (40 g)
Protection Type IP20
Approvals CSA, UL Recognized File No. E164102